ISQ
44 / 115
11-5.2

Péclet number

URNurn:iso:std:iso:80000:-11:ed-2:en:item:11-5.2
Download RDF.jsonld.ttl
https://metanorma.github.io/isq-smart/quantities/part-11/t11-5.2
urn:iso:std:iso:80000:-11:ed-2:en:item:11-5.2
ISQ Identifiers
ISO
urn:iso:std:iso:80000:-11:ed-2:en:item:11-5.2
IEC
urn:iec:std:iec:80000-11:2019:::item:11-5.2
Designations
ENPéclet number
FRnombre de Péclet
Symbol
P e
Notation systems
Rendered
P e
AsciiMath
Pe
LaTeX
P e

Definition

EN

relation between convective heat transfer rate and conductive heat transfer rate, expressed by

P e = v l / α ; where

v :: is speed (ISO 80000-3: Space and time),

l :: is length (ISO 80000-3: Space and time) in the direction of heat transfer, and

α :: is thermal diffusivity (ISO 80000-5: Thermodynamics)

FR

relation entre le débit de transfert de chaleur par convection et le débit de transfert de chaleur par conduction, exprimée par:

P e = v l / α ; où

v :: est la vitesse (ISO 80000-3: Space and time);

l :: est la longueur (ISO 80000-3: Space and time) dans la direction du transfert de chaleur; et

α :: est la diffusivité thermique (ISO 80000-5: Thermodynamics)

0

Notes

EN

The thermal Péclet number is also given by

P e = R e ⋅ P r ; where

R e :: is the Reynolds number (Reynolds number), and

P r :: is the Prandtl number (Prandtl number).

Compare with Péclet number <mass transfer>, Péclet number for mass transfer.

FR

Le nombre de Péclet thermique est également donné par:

P e = R e ⋅ P r ; où

R e :: est le nombre de Reynolds (Reynolds number); et

P r :: est le nombre de Prandtl (Prandtl number).

Comparer avec Péclet number <mass transfer>, nombre de Péclet pour transfert de masse.

Concept HierarchyPendrill (2024)
1dimensionless quantitiesLevel 0 · Kind

Ontology

Class Hierarchy

A physical quantity as defined in ISO/IEC 80000, with associated symbols, definitions, and units of measurement.

Instance IRI

isq:t11-5.2
PropertyValue
rdf:type
dcterms:identifier
11-5.2
skosxl:prefLabel
"Péclet number <heat transfer>"@en
skosxl:altLabel
"Pe"@en
skos:definition
relation between convective heat transfer rate and conductive heat transfer rate, expressed by stem:[Pe = vl//alpha]; w…
skos:note
The thermal Péclet number is also given by stem:[Pe = Re * Pr]; where stem:[Re]:: is the Reynolds number (<<t11-4.1>>)…
isq:hasDimension
smart:hasBindingnessType
dcterms:isPartOf