1.15.2 Test procedure
A surge generator shall be used with the performance characteristics as specified in the referenced standard. The test consists of exposure to surges for which the rise time, pulse width, peak values of the output voltage/current on high/low impedance load and minimum time interval between two successive pulses are defined in the referenced standard.
The characteristics of the generator shall be verified before connecting the EUT.
At least three positive and three negative surges shall be applied.
Unbalanced lines | Line to line | |
Line to earth | ||
Balanced lines | Line to earth |