In Force

BIPM CIPM-MRA

BIPM CIPM MRA-G-02 : 2010
Guidelines for the monitoring and reporting of the operation of quality systems by RMOs
.
BIPM CIPM-MRA

In Force



Guidelines for the monitoring and reporting of the operation of quality systems by RMOs

1.  Introduction

A central component of the CIPM MRA requires that signatory NMIs establish and maintain a Quality System (QS). Unlike the CMC situation, however, the CIPM MRA does not explicitly specify how signatory NMIs review, gain confidence and accept each other’s quality systems.

With regard to the establishment of a QS, the CIPM MRA provides for the following methods:

  1. an NMI that chooses for its calibration and measurement services a quality system that meets the requirements of ISO Guide 25 or equivalent for an NMI, assessed by an accreditation body fulfilling the requirements of ISO Guide 58, declares its calibration measurement capabilities and submits them to the local RMO for review and transmission to the Joint Committee for analysis and inclusion in Appendix C.

  2. an NMI that chooses to use a different way of assuring quality or chooses a different quality system, or ISO Guide 25 without third-party assessment, for its calibration and measurement services declares its calibration and measurement capabilities and submits them to the local RMO for review and transmission to the Joint Committee for analysis and inclusion in Appendix C.

Demonstration of competence and capability may require visits and examination of procedures by an NMI and/or by peers selected by the local RMO.

2.  Review Guidelines

Each RMOs should have an open process in place for the monitoring and review of the QS1 of each of their member NMIs and DIs and to to report on their acceptance or otherwise to the JCRB. The process followed for the review is decided by each RMO and it shall satisfy at least the following requirements.

3.  Requirements for the QS

The QS operated by the NMI should be:

The QS should cover all declared CMCs

3.1.  QS assessed by Accreditation Body

  • The claimed CMC uncertainty must not be smaller than the accredited uncertainties documented in the scope of accreditation

  • The NMI must submit the name of the accreditation body and the names of the technical assessors and the lead assessor who were involved in the assessment of the NMIs capabilities.

  • The accreditation body should operate according to ISO/IEC 17011(draft) and should be a signatory to the ILAC MRA.

3.2.  Self declared QS

  • Where the QS is based on ISO/IEC 17025 the RMO must satisfy itself that the quality system complies with the standard.

  • Where the QS is not based on ISO/IEC 17025 the following must be addressed:

  • Organizational and Management requirements including:

    • quality manual ;

    • document control process ;

    • contract review ;

    • complaints ;

    • control of non conforming work;

    • corrective and preventative actions ;

    • internal audits and management review.

  • Technical requirements including:

    • Personnel

    • Accommodation and environment conditions

    • Test and calibration methods and method validation

    • Equipment

    • Calibration and measurement traceability

    • Assuring the quality of results

    • Reporting of results

    • Sampling and handling of items (where applicable).

4.  Report Guidelines

As part of the regular reports to the JCRB, the RMOs must provide annual summary reports on the status of the QS of the NMIs and DIs in their region,.

The report should include:

5.  Periodic Reviews of the Quality Management Systems

The quality management systems implemented to support the calibration and measurement capabilities of the NMIs and DIs must undergo a full review with a period not longer than five years. The individual RMOs are responsible for this review, under the auspices of their respective quality system working groups.

This comprehensive periodic review includes examination of evidence for the continued validity and vitality of published CMCs.

In addition to the 5-year review of the supporting QMS, CMCs published in the KCDB undergo continual monitoring to ensure their validity. NMIs and DIs are responsible for demonstrating that they are maintaining quality systems, including regular review of their services. All DIs and NMIs with published CMCs submit annual quality reports to their RMOs which include full disclosure of any issues (e.g., departure of key staff, loss of facilities and equipment, poor performance in comparisons with other NMIs and DIs, etc.) that would affect published CMCs.

6.  List of Acronyms

CIPM MRA

Mutual Recognition Arrangement

CMC

Calibration and Measurement Capability

JCRB

Joint Committee of the RMOs and the BIPM

NMI

National Metrology Institute

QS

Quality System

RMO

Regional Metrology Organization

7.  Revision History

Version number

Date of Issue/Review

Summary of change

2 2008-11-18

Initially approved as JCRB 10/8 (1c)
Reformatted by JCRB Executive Secretary, November 2008

3 2010-09-29

General review, new chapters 3 and 5. Approved by the JCRB.

2010-10-15 Changes approved by CIPM.

Document Control

Authors: